ALARA

Simulation and calculation engineering

Simulation and Calculations

Pressure, smoke, evacuation and structural-fire analyses are the basis of performance verification. ALARA turns risk into measured data with CFD and engineering calculations.

Stair pressurisation

Positive pressure-difference calculations and fan-capacity analysis.

Lift pressurisation

Calculations that keep smoke out of the firefighting lift.

Atrium and corridor analysis

Smoke-layer height and visibility.

Car-park and shelter smoke control

Jet-fan layout and the distribution of CO and heat.

Tunnel ventilation simulation

Emergency scenarios modelled with CFD and SES.

Fire effect on steel

Calculations of the fire effect on structural steel.

Smoke production

Smoke-production calculations.

3D and CFD smoke simulation

3D and CFD smoke-production simulations.

Smoke-control simulation

Smoke-control simulations.

Smoke-exhaust calculation

Smoke-exhaust calculations.

Pressurisation calculations

Pressurisation calculations.

Evacuation simulation

Evacuation simulations.

Critical evacuation time

Critical evacuation-time calculations.

Battery and voltage drop

Battery and voltage-drop calculations.

Audible and visual alarm layout

Layout analysis for audible and visual alarms.

Hydraulic calculations

Hydraulic calculations.

Clean-agent quantity and pipe size

Clean-agent quantity and the preliminary pipe diameter.

CFD, SES and the engineering calculations are verified by the specialist team.

Request a technical analysis

From clients

We worked with the ALARA team on modernising the fire-detection systems at our industrial plant. Both project management and commissioning were thoroughly professional. On-time delivery and complete technical documentation made the work much easier.

Ahmet D.
Plant Manager / Energy

They took on fire-safety design and site inspection at our construction site. The team's command of the field and their rigour on the standards were genuinely impressive. ALARA is now a solution partner on our projects.

Zeynep K.
Occupational Health and Safety Coordinator

We asked ALARA to integrate the fire-automation systems into our BMS. The integration was uneventful, the reporting screens are easy to use, and their continued support moved the operation forward.

Murat T.
Building Management Systems Specialist

Questions

Which stages does your fire engineering service cover?

It covers pre-design risk analysis, system design, hydraulic calculations, material selection, installation review and commissioning inspections. The whole process follows international NFPA and EN standards.

Can fire protection systems be integrated with building automation?

Yes. ALARA specialises in this. We integrate fire systems with BMS, SCADA or PLC infrastructure so the whole building can be supervised from one centre.

How often do you provide periodic maintenance?

It depends on the site. We typically recommend a check every six months and a full test once a year, with 24/7 emergency support when required.

Do you work on projects outside Turkey?

Yes. There are 1,134 reference projects in 41 countries. Experience is 37 years in the home country and 33 years abroad, covering design, supervision, testing and commissioning, and consulting.

Who are the training and consulting services for?

We prepare dedicated programmes for our clients' technical teams, maintenance staff and occupational safety specialists. Training is planned project by project, on site or remotely.

From the practice